Eldar Electric relying on distribution of the two prominent UPS Brand APC and Gutor has become a strategic supplier in the industrial and office markets for all major local and foreign customer like Nobel Oil, Socar, BP, OGPC, Azpromo, Petkim, Statoil, CET.
MGE EPS 7000 500 kVA
Uniquely designed to accept input power from any single phase, 120V power source such as a UPS, solar panel or other alternative energy power inputs.
Manageability
- Intuitive monitoringStep by step navigation and menu screens for critical system information and data. Information is easy to access and presented in a very intuitive way.
Availability
- High availability architectureDifferent running modes : hot stand-by, integrated parallel, or centralized static switch for multi-modules leading to availability architectures
Compatibility
- Output synchronization to external sourceUPS systems can be synchronized with any other independent source for use with downstream static transfer switches.
- Parallel capabilityMultiple units can be placed in parallel to meet power capacity and redundancy requirements
Output
- Output power capacity270.0 KWatts / 300.0 kVA
- Max Configurable Power (Watts)270.0 KWatts / 300.0 kVA
- Nominal Output Voltage480V 3PH , 600V 3PH
- Output Voltage DistortionLess than 2%
- Output Frequency (sync to mains)60 Hz
- Output Frequency (not synced)60Hz +/- 0.1% for 60Hz nominal
- Load Crest Factor3.5 : 1
- TopologyDouble Conversion Online
- Waveform typeSine wave
- Overload Operation10 minutes @ 125% and 60 seconds @ 150%
- Output Voltage Tolerance+/- 0.5% static and +/- 2.5% 100% load step
- BypassBuilt-in Static Bypass, External Manual Bypass
Input
- Nominal Input Voltage480V 3PH , 600V 3PH
- Input frequency60 Hz +/- 3 Hz
- Input ConnectionsHard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G)
- Input voltage range for main operations408 - 552 (480)V
- Input Total Harmonic DistortionLess than 10% for the full load
- Type of Input Protection Required3-pole breaker
- Input Power Factor at Full Load0.9
Batteries & Runtime
- Battery typeVRLA
- Nominal Battery Voltage480V
- Expected Battery Life (years)5 - 10
- Efficiency in Battery Operation95.0 %
- Efficiency
Communications & Management
- Control panelMulti-function LCD status and control console
- Emergency Power Off (EPO)Yes
- Available SmartSlot™ Interface Quantity3
Physical
- Maximum Height82.01inches ( 2083mm , 208.3CM )
- Maximum Width69.02inches ( 1753mm , 175.3CM )
- Maximum Depth39.02inches ( 991mm , 99.1CM )
- Net Weight6899.2lbs. ( 3136.0KG )
- Shipping weight6998.2lbs. ( 3181.0KG )
- Shipping Height92.01inches ( 2337mm , 233.7CM )
- Shipping Width79.02inches ( 2007mm , 200.7CM )
- Shipping Depth42.99inches ( 1092mm , 109.2CM )
- ColorLight grey
Environmental
- Operating Temperature32 - 104 °F ( 0 - 40 °C )
- Operating Relative Humidity5 - 90 %
- Operating Elevation0-3333ft ( 0-999.9meters )
- Storage Temperature-20 - 45 °C
- Storage Relative Humidity5 - 90 %
- Storage Elevation0-30000ft ( 0-9000meters )
- Audible noise at 1 meter from surface of unit75.0dBA
- Online thermal dissipation59400.0BTU/hr
Conformance
- ApprovalscUL Listed, FCC Part 15 Class A, UL 1778
- Standard warranty1 year repair or replace
General
- Max Bypass Input Current361.0A