Warning: Use of undefined constant ru - assumed 'ru' (this will throw an Error in a future version of PHP) in /home/eldarelectric/public_html/Options/Lang/ru.php on line 13
APC DIN Rail - Panel Mount UPS with Standard Battery 500VA 230V / APC / Продукты / Eldar Electric

Продукты

Полагаясь на дистрибуцию двух известных брендов UPS APC и Gutor ООО “Eldar Electric” превратился в стратегического поставщика на промышленном и офисном рынке для многих местных и зарубежных клиентов, таких как Nobel Oil, Socar, BP, OGPC, Azpromo, Petkim, Statoil, CET.

APC DIN Rail - Panel Mount UPS with Standard Battery 500VA 230V

The Industrial Panel and DIN Rail AC UPS from APC by Schneider Electric offers protection from under voltage (sag) and over voltage (swell/surge), transients, spikes and unexpected power outages due to utility interruptions or problems within the facility.

 

  • The small form-factor is optimized for mounting within control panel enclosures either on a heavy-duty DIN rail or directly to the wall of the enclosure. The UPS battery can be loaded in the internal battery compartment or mounted externally depending on local codes. Frequently used to protect Industrial Process Control equipment, this AC UPS can provide protected AC power to multiple AC/DC power supplies within the cabinet. 

     

    • Easy Maintenance

      User replaceable battery - safely and simply replaceable by end-user with easy front panel access to the battery compartment; technician not required

      Hot swappable battery - replaceable by end-user or service personnel while UPS is operating on utility power

      Battery replacement - perform as part of preventive maintenance or based on UPS notification when 'UPS Automatic Self-Test' determines battery should be replaced
    • Flexible Installation

      Small form factor - optimized for mounting within control panel enclosure either on heavy duty DIN rail or directly to the wall of the enclosure

      Hardwired AC Input/Output - connection easily accessed on front panel of UPS

      UPS battery installation - either insert into the internal battery compartment or mount externally depending on local electrical codes

      Chassis knockout - choose either right side or bottom knockout for flexible positioning of externally mounted battery
    • Highly Available and Reliable

      Temperature compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature

      Automatic self-test - runs periodically to ensure early detection of a battery that needs replacing - Default interval for self-test is 14 days
    • Manageable

      LED Indicators - located on front of UPS provide status at a glance indicating On-Line, On-Battery, Battery-disconnected or needs replacement, UPS fault

      DB-9 serial communication port - uses RS232 protocol

      Integrated Dry Contact I/O - provides simple status information for On-Battery / Low Battery and user configured emergency power off (EPO)

      APC SmartSlot - accepts optional accessory cards for Network Management or Serial Modbus/Jbus or additional Relay I/O Dry Contacts - Integrated Dry Contact I/O is disabled when accessory card is installed 

      APC DIN Rail - Panel Mount UPS with High Temp Battery 500VA 120V

      Proven Industrial UPS power protection for control applications and harsh environments.

      Includes : CD with software , Documentation CD , Installation guide , Smart UPS signalling RS-232 cable

      • User-replaceable batteries
        Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

       

      Availability
      • Automatic self-test
        Periodic battery self-test ensures early detection of a battery that needs to be replaced.
      • Automatic restart of loads after UPS shutdown
        Automatically starts up the connected equipment upon the return of utility power.
      • Power conditioning
        Protects connected loads from surges, spikes, lightning, and other power disturbances.
      • Wide input voltage range
        Designed for harsh electrical environments to save battery life.
      • Cold-start capable
        Provides temporary battery power when the utility power is out.

      Manageability
      • Intelligent battery management
        Maximizes battery performance, life, and reliability through intelligent, precision charging.
      • LED Indicators
        Provide easy-to-read status of the unit and utility power conditions.
      • SmartSlot
        Customize UPS capabilities with management cards.
      • Optional Dry Contact I/O Accessory
        Each Dry Contact I/O Accessory increases the number of input contacts by 2 and output relays by 1

      Serviceability
      • Technical support
        Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it.
      • Hot-swappable batteries
        Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
      • User-replaceable batteries
        Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

      Adaptability
      • Flexible Design
        Available in a wide range of configurations to suit any operating environment
      • Plug-and-Play external batteries
        Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
      • Multiple mounting methods
        Allows for standardization on one product for use in different environments.

     

Download brochure