Продукты
Полагаясь на дистрибуцию двух известных брендов UPS APC и Gutor ООО “Eldar Electric” превратился в стратегического поставщика на промышленном и офисном рынке для многих местных и зарубежных клиентов, таких как Nobel Oil, Socar, BP, OGPC, Azpromo, Petkim, Statoil, CET.
Symmetra MW 600kW Frame, 480V
Includes: Assembly service , Installation Guide , Start-Up Service , User Manual
Availability
- Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.
- Network manageableProvides remote power management of the UPS over the network.
- Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
- Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
- Audible alarmsProvides notification of changing utility power and UPS power conditions
- Configurable for N+1 internal redundancyProvides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
- Power Modules connected in parallelEnhances availability by allowing immediate, seamless recovery from isolated module failures.
Total Cost of Ownership
- Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
- Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
- Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
- Manageable external batteriesReduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.
- Fully-rated power kVA equals kWReduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
- Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
- Compatible with Schneider Electric's lithium ion battery solutionReduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictablity and manageability.
Click here for more details.
Sustainability
- EU CoC for UPSEnsures that UPSs sold in the EU are highly efficient
Agility
- Multiple cable-entry pointsProvides flexibility of UPS placement in the room and easy access to install cabling to the terminal blocks.
- Front-access servicingSimplifies installation and UPS maintenance while minimizing space requirements.
- Parallel-capacity capableIncreases total power capacity by using multiple uninterruptible power supplies simultaneously.
- Scalable runtimeAllows additional run time to be quickly added as needed.
- Parallel-redundant capablePower the connected equipment with multiple uninterruptible power supplies to increase system redundancy
- Scalable power capacityReduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
Marketing Features
- Power Modules connected in parallelEnhances availability by allowing immediate, seamless recovery from isolated module failures.
- Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
- Configurable for N+1 internal redundancyProvides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
- LCD displayProvides schematic overview of critical data for guided operation and troubleshooting on color LCD touch-screen.
- Scalable power capacityReduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
- Fully-rated power kVA equals kWReduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
- Battery modules connected in parallelDelivers higher availability through redundant batteries.
- Input power factor correctionEliminates the need for an external phase-compensation unit and minimizes installation costs by enabling the use of smaller generators and cabling.
- Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.
-