Продукты
Полагаясь на дистрибуцию двух известных брендов UPS APC и Gutor ООО “Eldar Electric” превратился в стратегического поставщика на промышленном и офисном рынке для многих местных и зарубежных клиентов, таких как Nobel Oil, Socar, BP, OGPC, Azpromo, Petkim, Statoil, CET.
Symmetra PX 500kW Scalable to 500kW with Maintenance Bypass Left & Distribution
A high-performance, 3-phase, modular, scalable, power protection solution with industry-leading efficiency, capacity, and performance for medium to large data centers and mission-critical environments.
Multiple UPSs can be installed in parallel for ultra-efficient system redundancy or up to 2MW of power protection. Parallel installations with custom switchgear and installations using a 3rd-party maintenance bypass panel require the APC Symmetra PX250/500 Third Party Switchgear Kit for breaker monitoring and EPO functionality.
Call for Availability
800-800-4272
800-800-4272
Includes: Assembly service , Installation guide , Network Management Card , Start-Up Service , User Manual
- Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced.
- Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
- Battery modules connected in parallelDelivers higher availability through redundant batteries.
- Battery replacement without toolsEnables fast battery replacement, lowering Mean Time to Repair (MTTR).
- Dual mains inputIncreases availability by allowing the UPS to be connected to two separate power sources.
- ECO ModeOperating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
- Front-access servicingSimplifies installation and UPS maintenance while minimizing space requirements.
- Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
- LCD graphics touch screen displayFull color text and mimic diagrams that easily display modes of operation, systems parameters and alarms.
- Mega TieDuring maintenance procedures, maintain full protection by transferring the load from one independent Symmetra PX 250/500kW system to another.
- Output synchronization to external sourceUPS systems can be synchronized with any other independent source for use with downstream static transfer switches.
- Parallel-capacity capableIncreases total power capacity by using multiple uninterruptible power supplies simultaneously.
- Parallel-redundant capablePower the connected equipment with multiple uninterruptible power supplies to increase system redundancy
- Remote DisplayDownload the display interface to your laptop or personal computer. Remotely monitor the UPS and configure a sub-set of UPS parameters. Note: Remote start-up and shutdown are not supported.
- Scalable runtimeAllows additional run time to be quickly added as needed.
- Supports 3rd party maintenance bypassThe APC Symmetra PX250/500 Third Party Switchgear Kit is required for installations with custom switchgear or a 3rd-party maintenance bypass panel. The boards in this kit monitor the breakers and provide EPO functionality.
- Swappable batteriesAllows quick addition of runtime capacity or replacement of existing battery modules. Installed modules are automatically recognized by the system.
- Temperature-compensated battery chargingProlongs battery life by regulating the charge voltage according to battery temperature.
- Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
- User-replaceable power modulesEnables simple upgrades and replacements of the Power Modules.
- User-replaceable batteriesIncreases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Network manageableProvides remote power management of the UPS over the network.
- Fully-rated power kVA equals kWReduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
- Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.
- Configurable for N+1 internal redundancyProvides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
- Power Modules connected in parallelEnhances availability by allowing immediate, seamless recovery from isolated module failures.
- Battery modules connected in parallelDelivers higher availability through redundant batteries.
- Scalable power capacityReduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
Availability
- Automatic internal bypassSupplies utility power to the connected loads in the event of a UPS power overload or fault.
- Network manageableProvides remote power management of the UPS over the network.
- Modular designProvides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
- Swappable power modulesAllows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.
- Power Modules connected in parallelEnhances availability by allowing immediate, seamless recovery from isolated module failures.
- Configurable for N+1 internal redundancyProvides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
- Redundant Intelligence ModulesProvides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
Agility
- Scalable power capacityReduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
- Programmable frequencyEnsures compatibility with different input frequencies.
- SmartSlotCustomize UPS capabilities with management cards.
Total Cost of Ownership
- Input power factor correctionMinimizes installation costs by enabling the use of smaller generators and cabling.
- Generator compatibleEnsures clean, uninterrupted power to protected equipment when generator power is used.
- 5x8 Start-up service includedRequired for full coverage of factory warranty
- Fully-rated power kVA equals kWReduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
Sustainability
- EU CoC for UPSEnsures that UPSs sold in the EU are highly efficient
- ENERGY STAR for UPSEstablishes that the efficiency of the UPS is in the top 25% of the market as verified by third party testing
Manageability
- LED status indicatorsQuickly understand unit and power status with visual indicators.
- Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
- Audible alarmsProvides notification of changing utility power and UPS power conditions