Magnum VS 50 W/SNMP -- 1X60A CB Distribution / APC / Products / Eldar Electric

Products

Eldar Electric relying on distribution of the two prominent UPS Brand APC and Gutor has become a strategic supplier in the industrial and office markets for all major local and foreign customer like Nobel Oil, Socar, BP, OGPC, Azpromo, Petkim, Statoil, CET.

Magnum VS 50 W/SNMP -- 1X60A CB Distribution

Automatic battery float voltage temperature compensation extends battery life and performance


Warning: count(): Parameter must be an array or an object that implements Countable in /home/eldarelectric/public_html/smarty/templates_c/view/1b946c37f970bb6826cb8fcf527ee297ec439273_0.file.ProductProductsView.tpl.php on line 48

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/eldarelectric/public_html/smarty/templates_c/view/1b946c37f970bb6826cb8fcf527ee297ec439273_0.file.ProductProductsView.tpl.php on line 82
  • Cable Entry
    Configurable for either top or bottom cable entry.
  • Dry Contact inputs
    User assignable inputs allow other equipment alarms to be monitored through the power system controller
  • Integral low voltage disconnect
    Automatic LVD function extends battery life by preventing damage caused by deep discharge.
  • Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Automatic restart of loads after UPS shutdown
    Automatically starts up the connected equipment upon the return of utility power.
  • User-replaceable batteries
    Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Front Access
    Installation and maintenance of all components can be carried out without access to the rear or sides of the cabinet.

Manageability
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • LED Indicators
    Provide easy-to-read status of the unit and utility power conditions.
Availability
  • Battery voltage temperature compensation
    Automatic battery float voltage temperature compensation extends battery life and performance
  • Extendable Run Time
    Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
  • Internal Protection
    Integral over-current protection devices protect the system against overload faults.
Download brochure