Warning: Use of undefined constant az - assumed 'az' (this will throw an Error in a future version of PHP) in /home/eldarelectric/public_html/Options/Lang/az.php on line 13
Magnum VS 50 W/SNMP -- 2X30A CB Distribution / APC / Məhsullar / Eldar Electric

Məhsullar

Ən məşhur iki UPS markası olan APC və Gutor-un paylanmasına etimad edən “Eldar Electric” MMC Nobel Oil, Socar, BP, OGPC, Azpromo, Petkim, Statoil, CET kimi bir çox böyük yerli və xarici müştərilər üçün sənaye və ofis bazarında strateji təchizatçıya çevrilmişdir.

Magnum VS 50 W/SNMP -- 2X30A CB Distribution

Automatic battery float voltage temperature compensation extends battery life and performance


Warning: count(): Parameter must be an array or an object that implements Countable in /home/eldarelectric/public_html/smarty/templates_c/view/1b946c37f970bb6826cb8fcf527ee297ec439273_0.file.ProductProductsView.tpl.php on line 48

    Warning: count(): Parameter must be an array or an object that implements Countable in /home/eldarelectric/public_html/smarty/templates_c/view/1b946c37f970bb6826cb8fcf527ee297ec439273_0.file.ProductProductsView.tpl.php on line 82
  • Cable Entry
    Configurable for either top or bottom cable entry.
  • Dry Contact inputs
    User assignable inputs allow other equipment alarms to be monitored through the power system controller
  • Integral low voltage disconnect
    Automatic LVD function extends battery life by preventing damage caused by deep discharge.
  • Hot-swappable batteries
    Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Automatic restart of loads after UPS shutdown
    Automatically starts up the connected equipment upon the return of utility power.
  • User-replaceable batteries
    Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Front Access
    Installation and maintenance of all components can be carried out without access to the rear or sides of the cabinet.

Manageability
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • LED Indicators
    Provide easy-to-read status of the unit and utility power conditions.
Availability
  • Battery voltage temperature compensation
    Automatic battery float voltage temperature compensation extends battery life and performance
  • Extendable Run Time
    Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
  • Internal Protection
    Integral over-current protection devices protect the system against overload faults.
Download brochure